Fluke FLK-87-VMAX CAL Heavy-Duty True-RMS Multimeter
The Fluke 87V MAX True-RMS Digital Multimeter with Calibration Certificate offers peak performance and accuracy for troubleshooting and diagnostics in demanding environments. It features a high-resolution display, extended AC voltage bandwidth, and built-in thermometer. Its rugged design is drop-tested to 4 meters and IP67 rated for dust and water resistance.
- Model
- Fluke FLK-87-VMAX CAL
- Calibration
- Available on request
- Price
- $660
- Status
- In stock
- RFQ ref
- FLK-87-VMAX CAL
This unit
The Fluke FLK-87-VMAX CAL is a heavy-duty true-RMS multimeter engineered for precision measurement and diagnostics in industrial environments. It delivers advanced troubleshooting capabilities with CAT III 1000 V / CAT IV 600 V safety ratings, IP67 waterproof/dustproof construction, and 4-meter drop protection. The instrument combines high-resolution measurement accuracy with field-proven durability, making it suitable for maintenance technicians, system integrators, and field engineers working in electrically challenging environments.
Technical Specifications
Measurement Ranges- AC/DC Voltage: Up to 1000 V
- AC/DC Current: Up to 10 A (20 A for 30 seconds maximum)
- Frequency: Up to 200 kHz
- Temperature: Built-in thermometer capability
- Continuity and diode testing Display and Resolution
- 19,999 count digital display (4½-digit resolution)
- Dual display modes: 6,000 or 20,000 counts
- Large digits with 2-level bright white backlight
- Analog bargraph for real-time signal trending Environmental Ratings
- Operating Temperature: −15 °C to +55 °C (−40 °C for 20-minute intervals)
- Relative Humidity: Up to 95%
- IP67 rating: complete dust and water immersion protection
- Drop rated to 4 meters (13 feet) Power
- Three AA batteries
- Battery life: Up to 800 hours
- Tool-free battery access door (maintains calibration seal)
Key Features
- True-RMS measurement for accurate AC voltage and current on non-linear loads
- Min/Max/Average recording with 250 µs peak capture window
- Low-pass filter for VFD and noisy industrial equipment measurements
- High-frequency noise shielding for clean readings in electromagnetically hostile environments
- Backlit keypad and bright display for visibility in low-light field conditions
- Calibration certificate included; accuracy maintained for 2 years post-calibration at 18 °C to 28 °C
Typical Applications
- Motor and drive troubleshooting on variable frequency drives
- Electrical system diagnostics and preventive maintenance
- Power quality assessment in industrial facilities
- Temperature monitoring with integral probe capability
Compatibility & Integration Supplied with Premium TL175 TwistGuard™ test leads, temperature probe, and alligator clips for immediate field deployment.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | Up to 200 kHz | Voltage / Current Range: AC/DC Voltage: Up to 1000 V |
| AC/DC Current | Up to 10 A (20 A for 30 seconds) |
Fluke FLK-87-VMAX CAL — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke FLK-87-VMAX CAL. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke FLK-87-VMAX CAL faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke FLK-87-VMAX CAL price
This Fluke FLK-87-VMAX CAL is listed at $660. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke FLK-87-VMAX CAL calibration cost
NIST-traceable calibration for the Fluke FLK-87-VMAX CAL is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →