Anritsu MA2444D Series – High Accuracy Diodes Sensors (CW)
Anritsu MA2444D Series High Accuracy Diode Sensors (CW) are engineered for consistent and repeatable power measurement across wide frequency ranges. Their rugged design and linear response make them suitable for laboratory and field testing of high-frequency RF components.
- Model
- Anritsu MA2444D Series
- Calibration
- Available on request
- Price · starting from
- $850
- Status
- In stock
- RFQ ref
- MA2444D Series
This unit
The Anritsu MA2444D Series High Accuracy Diode Sensors deliver precise CW and TDMA power measurements across 10 MHz to 40 GHz. Built-in 3 dB attenuation minimizes input VSWR, critical for high-gain amplifier characterization. Calibration factors stored in internal EEPROM enable automatic power meter correction. Fast rise time and wide dynamic range support demanding RF and microwave test environments.
Technical Specifications Frequency & Power
Frequency range: 10 MHz to 40 GHz
Dynamic range: −67 dBm to +20 dBm (87 dB span)
Rise time: <0.004 ms at 0.0 dBm, room temperature
Sensor linearity: 2.5% below 40 GHz Impedance Matching
Built-in 3 dB attenuator reduces input VSWR
SWR performance varies by frequency band: - 10–50 MHz: <1.90 - 50–150 MHz: <1.17 - 150 MHz–2 GHz: <1.08 - 2–12.4 GHz: <1.16 - 12.4–18 GHz: <1.21 - 18–32 GHz: <1.29 - 32–40 GHz: <1.44 Connectors & Calibration
RF connector: K(m) with hexagon coupling nut for standard torque wrench attachment
Calibration factors: Stored in internal EEPROM for automatic correction
Key Features
87 dB dynamic range enables measurement from weak to strong signal levels
Fast 0.004 ms rise time captures transient behavior in TDMA and burst signals
Frequency-dependent SWR optimization ensures accurate readings across 10 MHz–40 GHz
Internal EEPROM eliminates manual calibration factor entry
Typical Applications
RF amplifier characterization and gain measurement
TDMA and pulsed power monitoring
CW power verification in production and field service
High-frequency component testing to 40 GHz
Compatibility & Integration Power Meters
ML2430, ML2480, ML2490 series compatible
ML2407A/08A and ML2437A/38A meters require firmware revision 3.10 or higher Software Support
PowerSuite software for ML2430A series - real-time trace viewing and data archiving
PowerMax™ software for ML2480B and ML2490A series - enhanced visualization and remote control
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 40 GHz | Power Range (dBm): '-67 dBm to +20 dBm |
Anritsu MA2444D Series — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2444D Series. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MA2444D Series price
This Anritsu MA2444D Series is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MA2444D Series calibration cost
NIST-traceable calibration for the Anritsu MA2444D Series is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →