Anritsu MA2474D – Standard Diode Sensor
The Anritsu MA2474D is a standard diode sensor designed for accurate power measurements. It features a wide frequency range and excellent sensitivity, making it suitable for various applications in RF and microwave testing. This sensor provides reliable performance and is an essential tool for engineers and technicians.
- Model
- Anritsu MA2474D
- Calibration
- Available on request
- Price · starting from
- $700
- Status
- In stock
- RFQ ref
- MA2474D
This unit
The Anritsu MA2474D is a standard diode sensor for precision RF and microwave power measurements from 10 MHz to 40 GHz. It delivers high accuracy across continuous wave and TDMA applications, with dynamic range spanning -70 dBm to +20 dBm and sensor linearity better than 1.8% below 18 GHz. The sensor integrates directly with Anritsu ML2430, ML2480, and ML2490 series power meters, offering engineers a fast, accurate measurement tool with rise time under 4 µs - ideal for GSM and modulated signal analysis.
Its 50 ohm input impedance, K-type male connector, and EEPROM-stored calibration factors ensure reliable operation in demanding test environments.
Technical Specifications
- Frequency Range: 10 MHz to 40 GHz
- Dynamic Range: -70 dBm to +20 dBm
- Maximum Input Power: 23 dBm CW; 30 dBm, 1 µs peak; ±20 Vdc
- Rise Time: < 4 µs
- Sensor Linearity: Better than 1.8% (10 MHz–18 GHz); 2.5% (10 MHz–40 GHz)
- Standing Wave Ratio: < 1.90 (10–50 MHz) to < 1.50 (32–40 GHz)
- Input Impedance: 50 ohms nominal
- RF Connector: K(m) with precision coupling nut
- Calibration: EEPROM-stored factors
Key Features
- Rise time under 4 µs enables accurate TDMA and GMSK modulation measurements on GSM systems.
- Measurement uncertainty includes instrumentation accuracy (≈0.5%) combined with sensor linearity performance.
- Precision RF connectors support torque wrench attachment for repeatable coupling.
- Calibration data embedded in sensor memory eliminates manual factor entry.
Typical Applications
- CW and TDMA power measurements requiring high dynamic range and accuracy.
- GSM and similar TDMA systems using GMSK modulation.
- General-purpose RF power measurement where linearity better than 1.8% is required.
Compatibility & Integration Designed for use with Anritsu ML2430, ML2480, and ML2490 series power meters.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 MHz to 40 GHz | Power Range (dBm): '-70 dBm to +20 dBm | Voltage / Current Range: ±20 Vdc |
Anritsu MA2474D — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MA2474D. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Anritsu MA2474D price
This Anritsu MA2474D is listed at $700. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MA2474D calibration cost
NIST-traceable calibration for the Anritsu MA2474D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →