JDS Uniphase OAB1552+20FP0
JDS Uniphase Optical Amplifiers. Wavelength: 980 nm.
- Model
- JDS Uniphase OAB1552+20FP0
- Calibration
- Available on request
- Price
- $5,200
- Status
- In stock
- RFQ ref
- OAB1552+20FP0
This unit
The JDS Uniphase OAB1552+20FP0 is a benchtop Erbium-Doped Fiber Amplifier (EDFA) engineered as a C-band booster amplifier for single-channel optical signal amplification across 1528–1563 nm. This unit delivers high gain and saturated output power to extend transmission reach in fiber optic communication systems, with flexible optical interfaces and rack-mount capability for laboratory and production environments.
Technical Specifications Optical Performance
Operating wavelength range: 1528–1563 nm
Amplifier window: 1528–1610 nm
Minimum small signal gain: 37 dB
Minimum saturated output power: 17 dBm
Maximum noise figure: 4.5 dB
Spectral gain flatness (maximum): 1.7 dB (p-p) over 1570–1603 nm
Maximum PDL: < 0.3 dB
Maximum PMD: 0.6 ps
Input/output isolation: 40/40 dB (minimum) Pump Laser & Interfaces
Pump wavelength: 980 nm
Maximum pump power achieves approximately 40 dB gain
Optical connectors: FC/PC, FC/APC, SC/PC, SC/APC
Signal configuration: Single channel Physical & Environmental
Dimensions: 21.2 × 8.9 × 35.5 cm
Weight: < 4 kg
Operating temperature: 0 to 50 °C
Storage temperature: -40 to 70 °C
Humidity (maximum): 95% RH non-condensing (0 to 45 °C)
Laser safety: FDA 21 CFR 1040.10 Class IIIb; maximum output power ≤ 24.5 dBm
Key Features
Front-panel LCD for real-time input/output power and current monitoring
RS232 remote control capability
Compact benchtop form factor with optional 19-inch rack-mount kit
High output power and gain over C-band window
Low polarization-dependent loss and mode dispersion
Compatible with JDS Uniphase Model 1200 Series power supply
Typical Applications
Pre-amplifier, booster, and in-line amplifier configurations
DWDM transmission for multichannel lightwave systems
Sonet/SDH single-channel systems
Component and sub-assembly manufacturing
Fiber optic research and development
Compatibility & Integration The OAB1552+20FP0 accepts external power via JDS Uniphase Model 1200 Series supplies and supports mid-span access for system integration. Multiple optical interface options enable straightforward connection to standard fiber patch panels and test setups.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | 17 dBm (minimum saturated output), maximum 24.5 dBm (laser safety limit) | Wavelength Range: 1528–1563 nm (operating), 1528–1610 nm (amplifier window) |
JDS Uniphase OAB1552+20FP0 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase OAB1552+20FP0. Calibration covers gain at rated input power across the specified wavelength range, noise figure at rated gain setting, output power accuracy, gain flatness across the C-band or specified wavelength range, and polarization-dependent gain (PDG) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase OAB1552+20FP0 faults: pump laser diode degradation (gain drop, reduced output power), TEC failure causing thermal drift, optical isolator degradation, power supply failure. The most common failure on any EDFA is pump laser diode degradation. Secondary faults include TEC failure causing thermal runaway, optical isolator degradation, and power supply failure.
JDS Uniphase OAB1552+20FP0 price
This JDS Uniphase OAB1552+20FP0 is listed at $5,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase OAB1552+20FP0 calibration cost
NIST-traceable calibration for the JDS Uniphase OAB1552+20FP0 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers gain at rated input power across the specified wavelength range, noise figure at rated gain setting, output power accuracy, gain flatness across the C-band or specified wavelength range, and polarization-dependent gain (PDG) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →