Advantest R6441D Digital multimeter

The Advantest R6441D is a digital multimeter designed for precision measurement and reliable performance. Ideal for electronics testing, quality control, and laboratory use, it offers high accuracy and a range of measurement functions.

Model
Advantest R6441D
Calibration
Available on request
Price
$879
Status
In stock
RFQ ref
R6441D
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R6441D is a 4.5-digit digital multimeter engineered for precision DC and AC measurements across R&D, production, and field environments. Dual-channel input architecture and dual display capability enable simultaneous multi-parameter monitoring, while enhanced current measurement performance and battery operation support portable deployment. True RMS AC measurement with crest factor tolerance and flexible interface options make this instrument suitable for diverse electrical characterization tasks.


Technical Specifications

Measurement Functions

  • AC/DC Voltage: up to 700 V AC; 0.001 V to DC range

  • AC/DC Current: up to 10 A (both AC and DC)

  • Resistance: up to 200 Ω

  • Frequency Measurement: supported AC Performance (R6441D)

  • True RMS measurement capability

  • Voltage filter range: 300 Hz to 100 kHz

  • Current filter range: 300 Hz to 5 kHz

  • Crest factor: 3:1 at full scale Voltage Input Impedance

  • DC: 1 GΩ or greater

  • AC: 1.1 MΩ ±10%, 100 pF or less Resistance Measurement

  • Applied current: 3 mA (200 Ω range) to 10 nA (200 MΩ range)

  • Open circuit voltage: 7.5 V maximum Accuracy

  • Resistance: ±0.07% ±10d

  • Current: ±0.2% ±5d

  • Temperature coefficient: 0.1 × (measurement accuracy)/°C (0–50°C operating range)

  • Reference conditions: 23 ± 5°C, 85% RH or less Overcurrent Protection

  • Standard ranges: 0.5 A/250 V IEC 127 sheet 1 fuse

  • 10 A range: 15 A/250 V with 10,000-A interrupting capacity Physical Characteristics

  • Weight: 1 kg maximum

  • Operating temperature: 0–50°C

  • Storage humidity: 85% RH or less


Key Features



  • Dual-channel simultaneous measurement

  • Dual independent displays

  • Calculation functions: null, smoothing, dB/dBm, scaling, MAX/MIN, comparator

  • Battery-powered for field portability


Typical Applications R&D laboratories, production line verification, field service and troubleshooting.


Compatibility & Integration Optional GPIB interface (Option 01) and memory card interface unit (R13222) support data logging and remote control integration.

Specifications

ParameterValue
Frequency Range300 Hz to 100 kHz (AC voltage filter)
300 Hz to 5 kHz (AC current filter) | Voltage / Current Range0.001 V to 700 V AC/DC

Advantest R6441D — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R6441D. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest R6441D faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Advantest R6441D price

This Advantest R6441D is listed at $879. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R6441D calibration cost

NIST-traceable calibration for the Advantest R6441D is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents