Burleigh SA-91 Interferometer

Burleigh SA-91 Interferometer,Enables accurate measurement of optical path differences and coherence length. Used for wavelength calibration and fiber dispersion analysis in fiber optic and laser systems. Durable for laboratory applications.

Model
Burleigh SA-91
Calibration
Available on request
Price
$6,479
Status
In stock
RFQ ref
SA-91
View cart

This unit

The Burleigh SA-91 is a high-finesse Fabry-Perot interferometer for precision spectral characterization of narrow-band lasers and optical sources. Built on confocal mirror geometry with thermally stable Invar construction, it delivers high spectral resolution across the visible through near-infrared spectrum. The instrument measures optical path differences, coherence length, laser linewidth, longitudinal mode structure, and frequency stability with exceptional accuracy.


Technical Specifications



  • Cavity Design: Confocal mirror geometry

  • Free Spectral Range: 2 GHz or 8 GHz

  • Finesse: >200 for wavelengths 300 for wavelengths ≥1000 nm

  • Minimum Resolvable Bandwidth: FSR/Finesse

  • Wavelength Range: 450 nm to 1.8 µm (interchangeable mirror sets); UltraBand™ coverage exceeds 250 nm per set

  • Mirror Reflectivity: 99.7% nominal

  • Transmission: >10%

  • Input Aperture: 1 mm

  • PZT Scan Distance: 1.2 µm/1000 V

  • PZT Non-Linearity: <1%

  • Scan Non-Linearity: <0.1% (with RG-91 electronic compensation)

  • Construction: Thermally stable Invar


Key Features



  • Interchangeable mirror sets span 450 nm to 1.8 µm without requiring instrument redesign

  • UltraBand™ wavelength coverage reduces number of mirror set changes needed during multi-wavelength experiments

  • High finesse enables sub-nanometer resolution

  • Four-axis alignment mount (SA-900) supports precise cavity positioning

  • Integrated PZT scanning with low non-linearity and electronic linearization


Typical Applications



  • Laser linewidth measurement

  • Longitudinal mode structure analysis

  • Frequency stability measurements

  • Wavelength calibration

  • Fiber dispersion analysis

  • Optical path difference measurements

  • Surface measurements


Compatibility & Integration The SA-91 operates within a modular system: the RG-91 Ramp Generator supplies piezoelectric scanning voltage with adjustable range, zero offset, and rate, plus non-linearity correction. The DA-100 Detector/Amplifier provides 0.1 V/mW to 1 V/µW sensitivity, 0.3–100 kHz bandwidth, and minimum detectable power of 1 nW (silicon, 633 nm) or 2 nW (germanium, 1.5 µm).

Specifications

ParameterValue
Frequency Range2 GHz or 8 GHz | Voltage / Current Range: 1.2 µm/1000 V (PZT scan)
0 to ±6 V output (DA-100) | Wavelength Range450 nm to 1.8 µm