Ametek / VTI Instruments / VXI Technology SMP2001A Power Switch Module
Ametek / VTI Instruments / VXI Technology VXI Modules. Voltage: 250 V AC / 125 V DC, Current: 16 A per channel, Channel: Mainframe Capacitance: 20 MHz.
- Model
- Ametek / VTI Instruments / VXI Technology SMP2001A
- Calibration
- Available on request
- Price
- $850
- Status
- In stock
- RFQ ref
- SMP2001A
This unit
The Ametek / VTI Instruments / VXI Technology SMP2001A is a power switch module for VXIbus and SMIPII™ systems, delivering high-capacity switching in a compact card-slot form factor. It has either 20 SPST or 10 DPST relay channels rated at 16 A per channel, capable of handling up to 250 V AC or 125 V DC. Maximum switching power reaches 300 W DC or 2000 VA per channel, with aggregate module capacity of 25 kW.
A fail-safe interrupt input enables automatic relay opening during safety-critical events.
Technical Specifications
- Switching Configuration: 20 SPST 16 A or 10 DPST 16 A channels
- Maximum Voltage: 250 V AC / 125 V DC
- Maximum Current: 16 A per channel
- Maximum Power: 300 W DC / 2000 VA per channel; 25 kW module aggregate
- Breakdown Voltage: 1,000 V RMS (open contacts)
- Path Resistance: 1×10⁹ Ω
- Thermal Offset (HI-LO): < 50 µV
- Open Channel Capacitance: < 20 pF
- Channel-Mainframe Capacitance: 20 MHz
- Switching Time: < 10 ms
- Mechanical Life: 5×10⁷ operations
- Electrical Life: 1×10⁵ operations at full load
Key Features
- Low insertion loss: < 0.2 dB at 100 kHz, < 0.5 dB at 1 MHz, < 1.0 dB at 10 MHz
- Excellent crosstalk isolation: < -75 dB at 100 kHz
- Fail-safe interrupt input for emergency power shutdown
- Driven from VXIbus +5 V supply
- Interchangeable with other SMIPII™ modules
Typical Applications
- AC line power switching
- DC and AC power supply control
- Industrial machinery and robotics relay control
- Automotive engine control circuits
- Solenoid switching
- Unit Under Test (UUT) power management
Compatibility & Integration The SMP2001A integrates into standard VXIbus card slots and operates within SMIPII™ mixed-card systems. The front-panel fail-safe interrupt line provides independent safety control independent of VXIbus communications.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 20 MHz | Voltage / Current Range: 16 A per channel, 250 V AC / 125 V DC |