Astronics / EADS / Talon Instruments SR112 8 Channel RS485 Differential Stimulus / Response Module
The SR112 is an 8-channel RS485 differential stimulus/response module designed for a variety of industrial applications. It offers reliable data transmission and reception over RS485 networks, with differential signaling for enhanced noise immunity. Ideal for automation, control, and data acquisition systems.
- Model
- Astronics / EADS / Talon Instruments SR112
- Calibration
- Available on request
- Price
- $1,250
- Status
- In stock
- RFQ ref
- SR112
This unit
The Astronics/EADS/Talon Instruments SR112 is an 8-channel RS485 differential stimulus/response module engineered for industrial data transmission and reception over RS485 networks. Differential signaling delivers enhanced noise immunity in automation, control, and data acquisition systems. The module integrates into VXI chassis environments as part of larger stimulus/response test systems, supporting reliable bidirectional communication with RS-485 standard compliance.
Technical Specifications
Channels: 8 differential RS485 stimulus/response channels
Standard: RS-485 compliant for balanced multipoint transmission
Data Rates: Up to 25 MHz; 50 MHz in multiplexed mode
Timing Rates: Up to 50 MHz
Channel Memory: Up to 128 Kbits per channel, expandable to 256 Kbits in multiplexed mode
Memory Architecture: Stimulus, Tristate, Record, Expect, and Mask
Input High Threshold: Typically 2.0 V
Input Low Threshold: Typically 0.8 V
Input Impedance: >10 kΩ
Output High Level: Typically >2.4 V
Output Low Level: Typically <0.4 V
Source Current: 50 mA
Sink Current: 50 mA
Output Impedance: 50 Ω
Short Circuit Protection: Standard on outputs
Key Features
Differential RS485 signaling for superior noise rejection
Stimulus generation and response capture on all 8 channels
Voltage support: TTL levels, RS485/422, and variable ±15 V or +5 V/−2 V options
Scalable memory per channel with multiplexed mode expansion
Operates within VXI chassis framework
Typical Applications
Industrial automation and control systems
Long-distance multipoint data acquisition
RS485 network stimulus/response testing
Noisy industrial environments requiring differential signaling
Compatibility & Integration The SR112 works with integration within VXI chassis housing. The SR192 Digital Test Module accommodates up to 12 I/O modules per chassis for 96 to 192 total channels. Multiple SR192 systems can be linked to reach 1152 channels within a single VXI chassis. Logic options include RS485/422, TTL, and ECL configurations.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 25 MHz (50 MHz multiplexed mode) |
| timing rates to 50 MHz | Voltage / Current Range | <0.4 V (low) |
| Source/Sink current | 50 mA, ±15 V or +5 V/−2 V (RS485/422 mode) |
| TTL | >2.4 V (high) |
Astronics / EADS / Talon Instruments SR112 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Talon Instruments SR112. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Astronics / EADS / Talon Instruments SR112 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Astronics / EADS / Talon Instruments SR112 price
This Astronics / EADS / Talon Instruments SR112 is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Astronics / EADS / Talon Instruments SR112 calibration cost
NIST-traceable calibration for the Astronics / EADS / Talon Instruments SR112 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →