Agilent/Keysight U2741A
The Agilent/Keysight U2741A is a modular, high-performance USB data acquisition (DAQ) device. It offers versatile analog and digital I/O capabilities for various measurement and automation applications. Featuring high sampling rates and resolution, it ensures accurate data capture.
- Model
- Agilent / Keysight U2741A
- Calibration
- Available on request
- Price
- $850
- Status
- In stock
- RFQ ref
- U2741A
This unit
The Keysight U2741A is a 5.5-digit USB modular digital multimeter delivering precision measurement across voltage, current, resistance, and specialized functions. Operating at up to 100 readings per second via high-speed USB 2.0 (USBTMC-USB488 compliant), it combines standalone portability with integration capability into the U2781A chassis for scalable test systems. Its compact, notebook-sized form factor - 117 mm × 180 mm × 41 mm with bumpers and 509 g mass - suits field deployment and space-constrained lab environments.
Technical Specifications
Measurement ranges span DC voltage from 1 µVDC to 300 VDC and AC voltage from 1 µVRMS to 250 VRMS. DC current measurement extends from 1 µADC to 2 ADC; AC current from 1 µARMS to 2 ARMS. The instrument supports 2-wire and 4-wire resistance measurement, continuity testing, diode characterization, frequency measurement, and temperature sensing via optional thermistor probe. Resolution reaches 5.5 digits with basic accuracy to 0.0025%. Common mode rejection exceeds 120 dB with 1 kΩ unbalanced load; normal mode rejection exceeds 60 dB at 50/60 Hz ±0.1%. Input protection rated at 300 VDC for voltage inputs and 2 A, 250 V fast-blown fuse for current. The module draws +12 VDC at 2 A maximum. Operating temperature range: 0°C to 55°C (full accuracy: 18°C to 28°C). Operating humidity: 50% RH non-condensing, or 50–90% RH at 40°C non-condensing. Storage temperature: –20°C to +70°C. Storage humidity: 5–90% RH non-condensing.Key Features
- High-speed USB 2.0 interface at 480 MBit/s
- CAT II 300 V over-voltage protection category
- Compact modular design fits U2781A mainframe or standalone operation
- 451 g shipping weight without bumpers
Compatibility & Integration Fully compatible with Keysight BenchVue, Measurement Manager (AMM), IO Libraries Suite, and IVI-COM drivers. Supports LabVIEW, VEE, Visual Studio, and MATLAB environments. Operates on Microsoft Windows (XP Professional or Home Edition recommended). Complies with IEC 61010-1, CAN/CSA-C22.2 No. 61010-1, ANSI/UL 61010-1, IEC 61326-2-2002/EN61326:1997+A1:1998+A2:2001+A3:2003, ICES-001, and AS/NZS CISPR11.
Agilent / Keysight U2741A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight U2741A. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight U2741A faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.
Agilent / Keysight U2741A price
This Agilent / Keysight U2741A is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight U2741A calibration cost
NIST-traceable calibration for the Agilent / Keysight U2741A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →