Ametek / VTI Instruments / VXI Technology VT1419A Multifunction Plus Module

Ametek / VTI Instruments / VXI Technology VXI Modules.

Model
Ametek / VTI Instruments / VXI Technology VT1419A
Calibration
Available on request
Price
$3,200
Status
In stock
RFQ ref
VT1419A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Ametek/VTI Instruments/VXI Technology VT1419A is a C-size, single-slot VXI multifunction module engineered for data acquisition and control in mixed-signal and mixed-sensor test environments. Register-based architecture supports flexible signal conditioning through interchangeable Signal Conditioning Plug-ons (SCPs), enabling both analog and digital input/output configurations without requiring additional VXI modules. On-board Engineering Unit (EU) conversion and real-time decision-making capabilities streamline measurement workflows while improving calibration accuracy and repeatability.


Technical Specifications



  • Form Factor: C-size, single-slot VXI module

  • Interface: Register-based VXIbus

  • Architecture: Scalable, multifunction design

  • Signal Conditioning: Interchangeable SCP modules (sold separately)

  • Data Processing: On-board EU conversion

  • Control: Real-time decision-making

  • NSN: 6625-01-645-8107


Key Features



  • Integrated signal conditioning reduces module count and enhances measurement repeatability

  • SCP modularity supports diverse input/output configurations including analog inputs with gain and filtering, frequency and period measurement, totalizing, PWM and FM signal processing, D/A conversion (voltage and current), digital outputs (8- or 16-bit), pulse generation with variable frequency and PWM control, and stepper motor control

  • Scalable architecture accommodates design verification of electromechanical components and assemblies

  • Terminal blocks supplied separately


Typical Applications



  • Design verification testing of electromechanical systems

  • Mixed-signal data acquisition

  • Multi-sensor monitoring and control

  • Real-time measurement and decision logic


Compatibility & Integration The VT1419A integrates into VXIbus-based test systems and works with Ametek/VTI Instruments/VXI Technology VXI modules and mainframes. SCP module selection determines specific input/output capabilities required for each test configuration.

Ametek / VTI Instruments / VXI Technology VT1419A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Ametek / VTI Instruments / VXI Technology VT1419A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Ametek / VTI Instruments / VXI Technology VT1419A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Ametek / VTI Instruments / VXI Technology VT1419A price

This Ametek / VTI Instruments / VXI Technology VT1419A is listed at $3,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Ametek / VTI Instruments / VXI Technology VT1419A calibration cost

NIST-traceable calibration for the Ametek / VTI Instruments / VXI Technology VT1419A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents