Astronics / EADS / Racal 1260-45A High-Density Switch Matrix (Option 01 or 01T Compatible)
The Astronics 1260-45A is a high-density switch matrix designed for signal routing applications. Compatible with Option 01 or 01T, it offers versatile connectivity and reliable performance in automated test equipment and communication systems.
- Model
- Astronics / EADS / Racal 1260-45A
- Calibration
- Available on request
- Price
- $1,850
- Status
- In stock
- RFQ ref
- 1260-45A
This unit
The Astronics / EADS / Racal 1260-45A is a C-size VXIbus high-density switch matrix module engineered for complex signal routing in automated test systems. This single-slot unit delivers eleven factory-configurable matrix arrangements - from four 4x16 matrices to a single 16x16 matrix - enabling flexible signal path management within a single chassis. The module switches signals up to 1 A and 250 VDC, with bandwidth performance ranging from 25 MHz (4x16, 4x32 configurations) to 20 MHz (4x64 configuration). Guard relays at row inputs provide non-latching behavior with automatic disconnect on power loss, protecting the Unit Under Test. Jumper-selectable bypass enables full latching relay operation for communication applications requiring maintained signal paths.
Technical Specifications
Form Factor: C-size, single-slot VXIbus module
Matrix Configurations: Eleven selectable arrangements including four 4x16, two 8x16, two 4x32, one 8x32, one 4x64, one 16x16, and hybrid combinations (two 4x16 + one 8x16, two 4x16 + one 4x32)
Switching Voltage: Up to 250 VDC or 300 VDC/ACrms maximum
Switching Current: Up to 1 A DC or ACrms per channel
Bandwidth (−3 dB): 25 MHz (4x16, 4x32); 20 MHz (4x64)
Channel Capacitance: <50 pF (open); <80 pF (closed)
Relay Type: Non-latching guard relays with jumper-selectable latching configuration
Mechanical Operations Rating: 10,000,000 cycles
Key Features
Guard relays at row inputs revert to open state on power loss, disconnecting signal paths from UUT
Configurable via factory settings, internal jumpers, and external cabling
External expansion capability for larger matrices within single chassis
Low closed-channel capacitance supports high-frequency signal integrity
Interfaces
VXIbus compliant
Compatible with Option 01 (native command set) and Option 01T (SCPI and register-based control)
IDC ribbon cable or crimp discrete wire connectors available
Physical Characteristics
Weight: 3.07 lb (1.38 kg) without Option 01
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 25 MHz (select configurations) |
| DC to 20 MHz (4x64) | Voltage / Current Range | Up to 250 VDC or 300 VDC/ACrms |
Astronics / EADS / Racal 1260-45A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Racal 1260-45A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Astronics / EADS / Racal 1260-45A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Astronics / EADS / Racal 1260-45A price
This Astronics / EADS / Racal 1260-45A is listed at $1,850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Astronics / EADS / Racal 1260-45A calibration cost
NIST-traceable calibration for the Astronics / EADS / Racal 1260-45A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →