IET / General Radio 1689M Precision Digibridge RLC Tester

The IET/General Radio 1689M Precision Digibridge is a versatile RLC tester designed for accurate and reliable measurement of resistance, capacitance, and inductance. It features a wide measurement range, high resolution, and multiple test frequencies, making it suitable for various component testing and quality control applications.

Model
IET / General Radio 1689M
Calibration
Available on request
Price
$4,800
Status
In stock
RFQ ref
1689M
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The IET / General Radio 1689M Precision Digibridge RLC Tester delivers high-accuracy measurements of resistance, inductance, and capacitance for component characterization, production testing, and R&D applications. This digital RLC meter accommodates a wide measurement span from milliohms to megaohms (R), microhenries to henries (L), and picofarads to millifarads (C), with selectable test frequencies and adjustable signal levels to match component requirements.

Technical Specifications Measurement parameters include resistance (R), inductance (L), and capacitance (C) across broad value ranges. The instrument operates at multiple test frequencies: 100 Hz, 120 Hz, 1 kHz, and 10 kHz. Test signal levels are adjustable from 0.1 Vrms to 1.0 Vrms nominal, accommodating voltage-sensitive components. Measurement ranges span:

Resistance: milliohms to megaohms

Inductance: microhenries to henries

Capacitance: picofarads to millifarads The digital display presents primary measurements (R, L, or C) alongside secondary parameters including Q factor, D factor, and equivalent series resistance (ESR).

Key Features Multiple test frequency selection enables component evaluation under varying operating conditions. The instrument configures for both series and parallel equivalent circuit representations, allowing flexibility in component analysis methodology. Auto/manual ranging capability simplifies operation across diverse component types. High-resolution digital readout ensures precise, detailed measurement presentation. Adjustable AC test signal voltage accommodates components with differing voltage sensitivities.

Typical Applications The 1689M serves production testing environments, quality control laboratories, and R&D operations where precise component characterization is essential. Engineers and system integrators employ it for passive component validation, filter design verification, and impedance analysis across frequency-dependent applications.

Compatibility & Integration The instrument integrates into laboratory test benches and production line quality assurance workflows, accepting standard passive components and supporting multiple measurement circuit configurations.

Specifications

ParameterValue
Frequency Range1 kHz, 10 kHz, 100 Hz, 120 Hz | Voltage / Current Range: 0.1 Vrms to 1.0 Vrms

IET / General Radio 1689M — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the IET / General Radio 1689M. Calibration covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common IET / General Radio 1689M faults: GPIB interface board failure, display failure, guard terminal switch contact wear, oscillator calibration drift on older analog bridges. HP 4284A and 4285A most common faults are HPIB interface board failure and display contrast loss. The internal oscillator and vector measurement circuits are highly stable and rarely fail. Wayne Kerr and GenRad bridge instruments may develop switch contact wear on decade resistance/capacitance dials.

IET / General Radio 1689M price

This IET / General Radio 1689M is listed at $4,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

IET / General Radio 1689M calibration cost

NIST-traceable calibration for the IET / General Radio 1689M is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents