Agilent/Keysight 34420A
Agilent / Keysight Laboratory Measurement Instruments. Accuracy: 0.003% over 1 year, Current: <, Voltage: Limited modes available.
- Model
- Agilent / Keysight 34420A
- Calibration
- Available on request
- Price
- $1,250
- Status
- In stock
- RFQ ref
- 34420A
This unit
The Keysight 34420A is a 7½ digit nanovolt/micro-ohm meter engineered for precision low-level measurements across voltage, resistance, and temperature applications. It delivers 100 pV sensitivity on DC voltage and 100 nΩ sensitivity on resistance, with exceptional 1.3 nVrms noise performance. The instrument combines a continuously integrating multi-slope III A-D converter with selectable analog and digital filtering to extract signals buried in noise-prone environments.
Technical Specifications
DC Voltage Measurement:- Ranges: 1 mV to 100 V
- Basic accuracy: 0.003% over 1 year; 2 ppm over 24 hours
- Input resistance: >10 GΩ (1 mV–10 V ranges); 10 MΩ ±1% (100 V range, Channel 1)
- Input bias current: <50 pA at 25 °C Resistance Measurement:
- Ranges: 1 Ω to 1 MΩ
- 4-wire and 2-wire selectable configurations
- Low Power Resistance and Voltage-Limited modes available
- Open circuit voltage: <14 V with selectable 20 mV, 100 mV, or 500 mV clamps Temperature Measurement:
- SPRT (ITS-90): −190 °C to +660 °C
- RTD (Type α = 0.00385/0.00392): R₀ from 4.9 Ω to 2.1 kΩ with IEC-751 conversion
- Thermocouple types B, E, J, K, N, R, S, T with ITS-90 conversion
- Accuracy: 0.003 °C Noise & Filtering:
- 1.3 nVrms; 8 nVpp performance
- Analog filter: 13 Hz low-pass, 2-pole (1 mV, 10 mV, 100 mV ranges)
- Digital filter: 10, 50, or 100 reading moving average
Key Features
- Built-in 2-channel low-noise scanner
- Ratio and difference measurement functions
- 1024-reading memory with statistics (Min, Max, Average, Peak-Peak, Standard Deviation)
- GPIB (IEEE-488) and RS-232 interfaces
- SCPI and Keithley 181 command compatibility
- Offset compensation for thermal EMF rejection
Physical & Electrical
- Dimensions: 104 mm H × 254 mm W × 374 mm D
- Weight: 7 lb
- Supply: 100 V/120 V/220 V/230 V/240 V ±10%; 45–66 Hz and 360–440 Hz auto-sensed
- Front panel: Shielded, low-thermal 99% copper contacts
Typical Applications Precision research metrology, device characterization, low-noise bridge balancing, thermal measurements in cryogenic systems, and calibration verification in standards laboratories.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 1 mV to 100 V (DC voltage) |
Agilent / Keysight 34420A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 34420A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 34420A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Agilent / Keysight 34420A price
This Agilent / Keysight 34420A is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 34420A calibration cost
NIST-traceable calibration for the Agilent / Keysight 34420A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →