HP / Agilent 4285A Precision LCR Meter, 75 kHz to 30 MHz
HP / Agilent Laboratory Measurement Instruments. Frequency Range: 75 kHz to 30 MHz at ±0.01% accuracy, Voltage: 5 mVrms to 2 Vrms (normal mode), Current: 200 µArms to 20 mArms (normal).
- Model
- HP / Agilent 4285A
- Calibration
- Available on request
- Price
- $5,472
- Status
- In stock
- RFQ ref
- 4285A
This unit
The HP/Agilent 4285A Precision LCR Meter delivers high-accuracy component and material characterization across RF and general-purpose measurement applications. Operating from 75 kHz to 30 MHz with 100 Hz frequency resolution, this benchtop instrument supports 14 measurement parameters including impedance, inductance, capacitance, resistance, quality factor, and dissipation factor. Basic accuracy reaches 0.1% for Z, C, and L measurements, with D accuracy of 0.001.
Technical Specifications
Measurement Coverage- Impedance: 0.01 mΩ to 99.9999 MΩ
- Capacitance: 0.01 fF to 999.999 µF
- Inductance: 0.001 nH to 99.9999 H
- Admittance: 0.01 nS to 99.9999 S
- Quality Factor (Q): 0.01 to 99999.9
- Phase Angle: −180.000° to 180.000° Signal Generation
- Frequency Range: 75 kHz to 30 MHz at ±0.01% accuracy
- Voltage: 5 mVrms to 2 Vrms (normal mode); 10 mVrms to 1 Vrms (constant mode)
- Current: 200 µArms to 20 mArms (normal); 100 µArms to 20 mArms (constant)
- Measurement Time: 30 ms, 65 ms, or 200 ms per measurement DC Bias
- Internal DC Bias Option: ±(1 mV to 40 V) at ≤100 mA with 0.1% accuracy
- External Bias Current Source Option: 0.01 A to 10 A DC Power & Environment
- Supply: 100/120/220 Vac ±10%, 240 Vac +5%/−10%; 47–66 Hz
- Consumption: 200 VA maximum
- Operating Temperature: 0° to 55°C; Humidity: <95% RH
- Dimensions: 426 mm W × 177 mm H × 498 mm D
- Weight: 16 kg (35.2 lb)
Key Features
- 14 measurement parameters including Rs, Rp, reactance, susceptance, and deviation
- High-speed 30 ms measurement capability for production throughput
- Precision test signal generation with voltage and current mode flexibility
- Optional power amplifier: 5 mVrms to 20 Vrms, 50 µArms to 200 mArms
Compatibility & Integration
- GPIB interface for automated test system integration
- Handler interface options (201/202) for component handler connectivity
- Scanner interface option (301) for multi-point testing
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 75 kHz to 30 MHz | Voltage / Current Range: 240 VAC, 5 mVrms to 2 Vrms |
HP / Agilent 4285A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 4285A. Calibration covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 4285A faults: GPIB interface board failure, display failure, guard terminal switch contact wear, oscillator calibration drift on older analog bridges. HP 4284A and 4285A most common faults are HPIB interface board failure and display contrast loss. The internal oscillator and vector measurement circuits are highly stable and rarely fail. Wayne Kerr and GenRad bridge instruments may develop switch contact wear on decade resistance/capacitance dials.
HP / Agilent 4285A price
This HP / Agilent 4285A is listed at $5,471.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 4285A calibration cost
NIST-traceable calibration for the HP / Agilent 4285A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. Turnaround is 1 to 3 business days after receipt. See full calibration details →