Anritsu 68097B Synthesized CW Generator, 0.01 – 65.0 GHz
Anritsu 68097B,Wideband CW signal generator from 10 MHz to 65 GHz. Provides excellent frequency stability, low phase noise, and support for automated test systems via remote interfaces.
- Model
- Anritsu 68097B
- Calibration
- Available on request
- Price
- $28,579
- Status
- In stock
- RFQ ref
- 68097B
This unit
The Anritsu 68097B is a synthesized CW generator covering 0.01 GHz to 65.0 GHz in a single coaxial output. Engineered for precision RF stimulus and swept measurement applications, it delivers ultra-low phase noise and exceptional frequency stability across demanding test environments. The instrument supports internal AM, FM, ØM, and pulse modulation, plus user-downloaded complex modulation.
Step sweep capability spans 1 to 10,000 steps with 1 kHz minimum step size (optional 0.1 Hz resolution) and configurable dwell times from 1 ms to 99 seconds. Alternate sweep mode enables frequency sweeping between two independently configured ranges at different power levels. Manual sweep provides stepped, phase-locked frequency adjustment with user-selectable step counts or sizes.
Remote interface support enables integration into automated test systems.
Technical Specifications
- Frequency Range: 0.01 GHz to 65.0 GHz
- Output Power: Maximum +17 dBm, minimum −125 dBm
- Phase Noise: −100 dBc/Hz SSB at 10 kHz offset from 10 GHz
- Frequency Resolution: 1 kHz standard; optional 0.1 Hz resolution available
- Step Sweep: 1 to 10,000 steps; dwell time 1 ms to 99 seconds; switching time <15 ms + 1 ms/GHz step size or <40 ms, whichever is less
- Modulation: Internal AM, FM, ØM, pulse; user-downloaded complex modulation supported
- Spurious Output: Low spurious signal performance
Key Features
- Alternate sweep mode with independent power levels per range
- Manual sweep with phase-locked frequency stepping
- Excellent frequency stability for long-term measurement confidence
- Remote interface capability for ATE system integration
Typical Applications
- Local oscillator replacement
- CW stimulus generation
- Swept component and subsystem analysis
- Signal simulation
- Automated test equipment integration
Compatibility & Integration Rackmount form factor with remote control interfaces for seamless incorporation into test automation systems. Economical upgrade paths to higher-performance models support evolving measurement requirements.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.01 GHz to 65.0 GHz | Power Range (dBm): '-125 dBm to +17 dBm |
Anritsu 68097B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 68097B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 68097B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 68097B price
This Anritsu 68097B is listed at $28,579. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 68097B calibration cost
NIST-traceable calibration for the Anritsu 68097B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →