Tenma Multimeter 72-7730A
Tenma Laboratory Measurement Instruments. Voltage: 200 mV to 1 kV, Voltage: 2 V to 1 kV, Current: 200 µA to 10 A.
- Model
- Tenma 72-7730A
- Calibration
- Available on request
- Price
- $230
- Status
- In stock
- RFQ ref
- 72-7730A
This unit
The Tenma 72-7730A is a handheld True RMS digital multimeter engineered for electrical and electronic testing across industrial, field service, and laboratory environments. This 4.5-digit (20,000-count) instrument delivers precise AC/DC voltage, current, resistance, capacitance, frequency, and temperature measurements with auto-ranging simplicity. The 100 kHz bandwidth supports transient analysis, while integrated duty cycle measurement (10% to 90%), diode testing, and continuity detection expand troubleshooting capability.
USB connectivity enables PC-based data logging of up to 100 records, making it suitable for continuous monitoring and documentation workflows.
Technical Specifications
Measurement Ranges & Accuracy- DC Voltage: 200 mV to 1 kV; ±(0.05%+5)
- AC Voltage: 2 V to 1 kV; ±(0.6%+40)
- DC Current: 200 µA to 10 A; ±(0.15%+20)
- AC Current: 200 µA to 10 A; ±(0.8%+15)
- Resistance: 200 Ω to 20 MΩ; ±(0.4%+20)
- Capacitance: 20 nF to 20 mF; ±(1.2%+20)
- Frequency: 20 Hz to 200 Hz; ±(0.1%+15)
- Temperature: −40°C to +1000°C; ±(1%+30)
- Duty Cycle: ±(1%+30)
- 4–20 mA Loop: 0–100% Input Protection & Safety
- Input Impedance: 2.5 GΩ (200 mV range); 10 MΩ (other ranges)
- Safety Rating: CAT III 1000 V, CAT IV 600 V
- Power: 9 V battery (6F22)
Key Features
- True RMS measurement for AC components on distorted waveforms
- Auto-ranging with manual override
- LCD display with full icon set and analogue bar graph
- Data Hold, Max/Min capture, and Relative Mode
- Current measurement alarm and low battery indication
- Auto power-off function extends battery life
- Diode test and continuity buzzer for circuit diagnostics
Typical Applications Field troubleshooting of power distribution and control circuits; preventive maintenance on industrial motor and drive systems; HVAC service diagnostics; telecommunications equipment testing; laboratory characterization of passive components.
Compatibility & Integration USB interface connects to Windows 8 compatible PC software for data acquisition and trend analysis.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 20 Hz to 200 Hz | Voltage / Current Range: DC Voltage: 200 mV to 1 kV |
| AC Voltage | 2 V to 1 kV |
| DC Current | 200 µA to 10 A |
| AC Current | 200 µA to 10 A |
Tenma 72-7730A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Tenma 72-7730A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Tenma 72-7730A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Tenma 72-7730A price
This Tenma 72-7730A is listed at $230. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Tenma 72-7730A calibration cost
NIST-traceable calibration for the Tenma 72-7730A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →