HP / Agilent 8443A TRACK GEN/COUNTR

HP / Agilent RF Signal Sources. Frequency range: 100 kHz to 110 MHz, Accuracy: ±0.3 dB (at 0 dBm, Resolution: 1 kHz (1 ms).

Model
HP / Agilent 8443A
Calibration
Available on request
Price
$628
Status
In stock
RFQ ref
8443A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 8443A is a dual-function test instrument combining a tracking generator and frequency counter in a single 3U chassis. The tracking generator produces CW signals from 100 kHz to 110 MHz with amplitude control from -120 dBm to +10 dBm, synchronizing output frequency to an external spectrum analyzer for swept-frequency device characterization. The integrated frequency counter measures signals across the same 100 kHz to 110 MHz range with selectable resolution down to 10 Hz, plus external signal measurement capability to 120 MHz. Five operational modes

Marker, Track Analyzer, Restore Signal, External, and Scan Hold - accommodate diverse RF and microwave testing workflows. Amplitude flatness of ±0.5 dB and absolute accuracy of ±0.3 dB at 0 dBm/30 MHz enable reliable component alignment in telecommunications, aerospace, and defense environments.

Technical Specifications Tracking Generator

Frequency range: 100 kHz to 110 MHz

Amplitude range: -120 dBm to +10 dBm (10 dB and 1 dB step attenuators plus 1.2 dB vernier)

Amplitude flatness: ±0.5 dB

Absolute amplitude accuracy: ±0.3 dB (at 0 dBm, 30 MHz)

Output impedance: 50 ohms, BNC connector, AC coupled

Reflection coefficient: ≤0.09 (1.2 SWR) with output <0 dBm

Modulation: Continuous Wave (CW) Frequency Counter

Measurement range: 100 kHz to 110 MHz (internal); 10 kHz to 120 MHz (external)

Resolution: 1 kHz (1 ms), 100 Hz (10 ms), 10 Hz (100 ms gate time)

Accuracy: ±1 count ± time base accuracy

Time base aging: <3 × 10⁻⁹ per day (post-warmup)

Time base temperature drift: <3 × 10⁻⁸ (0 to 55°C)

Digital output: 8,4,2,1 BCD code, positive logic Environmental & Power

Operating temperature: 0 to 55°C

Storage temperature: -40 to +75°C

Power input: 100/120/220/240 V ±10%, 48–440 Hz

Power consumption: 75 W typical; 30 W standby

Dimensions: 18-3/4" L × 16-3/4" W × 3-7/8" H (476 × 425 × 98 mm)

Weight: 24 lbs 5 oz (11.02 kg)

EMI: Meets or exceeds MIL-I-6181D

Key Features

Five operation modes for marker, tracking, signal restoration, external measurement, and scan-hold functions

Counter input accepts ±10 dBm to +25 dBm signals at 50 ohms

Switchable resolution and gate time for precision frequency measurement

1 MHz time base reference input/output (40 ohms, 1 Vrms minimum)

Typical Applications RF/microwave component alignment, frequency response characterization, signal source verification, and swept transmission measurements in conjunction with spectrum analyzers.

Compatibility & Integration Designed for integration with HP/Agilent spectrum analyzers including the 8553B and 8552A models via direct tracking and marker mode synchronization.

Specifications

ParameterValue
Frequency Range100 kHz to 110 MHz (generator)
10 kHz to 120 MHz (counter external input) | Power Range (dBm)'-120 dBm to +10 dBm | Voltage / Current Range: 100/120/220/240 V ±10%, 30 W standby, 48–440 Hz

HP / Agilent 8443A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 8443A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 8443A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

HP / Agilent 8443A price

This HP / Agilent 8443A is listed at $628. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 8443A calibration cost

NIST-traceable calibration for the HP / Agilent 8443A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →