Fluke 87-5 CAL Industrial True-RMS Multimeter

Fluke Laboratory Measurement Instruments. Voltage: 0–1000 V, Voltage: 0–1000 V RMS, Current: 0–10 A.

Model
Fluke 87-5 CAL
Calibration
Available on request
Price
$690
Status
In stock
RFQ ref
87-5 CAL
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 87-5 CAL Industrial True-RMS Multimeter is a field instrument engineered for precise electrical measurements across demanding industrial applications. It delivers True-RMS AC voltage and current readings on non-linear signals, with a dual-level backlit display optimized for variable lighting and an integrated thermometer for temperature measurement. Factory calibrated to NIST standards with traceable certification, the 87-5 CAL rapidly isolates faults in motor drives, plant automation, power distribution systems, and electromechanical equipment.

Technical Specifications Measurement Ranges

DC Voltage: 0–1000 V

AC Voltage: 0–1000 V RMS

DC Current: 0–10 A

AC Current: 0–10 A (20 A for up to 30 seconds)

Resistance: 0–50 MΩ

Capacitance: 0–10,000 µF

Frequency: 0–200 kHz

Temperature: Via integrated thermometer

Duty Cycle: Percentage measurement Accuracy

DC Voltage: ±0.05%

True-RMS AC Voltage: ±0.7% + 2 digits

DC Current: ±0.2% + 2 digits

True-RMS AC Current: ±1% + 2 digits

Key Features

3¾ digit display: 6,000 counts; high-resolution mode extends to 19,999 counts

Analog bar graph for transient and unstable signal visualization

Low-pass filter for VFD voltage and frequency accuracy

Peak capture detects transients at 250 µs response time

Min/Max/Average recording function

Touch Hold captures readings without probe contact

Relative mode eliminates test lead resistance in low-ohm measurements

Auto/manual ranging

Input alert audible warning

Transient voltage withstand rated to 8000 V spikes

Safety: EN 61010-1, CAT III 1000 V, CAT IV 600 V

IP30 enclosure rating

Dimensions: 7.35 in (L) × 3.41 in (W) × 1.25 in (H)

9 V alkaline battery; 400 hours typical runtime without backlight

Removable holster with integrated test lead and probe storage

Typical Applications Motor drive troubleshooting, plant automation diagnostics, power distribution analysis, electromechanical equipment service.

Included Components

NIST traceable calibration certificate with data

Test lead set (TL75)

Temperature probe (80BK)

Alligator clip set (AC175)

Holster

9 V battery

Specifications

ParameterValue
Frequency Range0–200 kHz | Voltage / Current Range: AC Current 0–10 A (20 A for 30 seconds), AC Voltage 0–1000 V RMS, DC Current 0–10 A, DC Voltage 0–1000 V

Fluke 87-5 CAL — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 87-5 CAL. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 87-5 CAL faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 87-5 CAL price

This Fluke 87-5 CAL is listed at $690. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 87-5 CAL calibration cost

NIST-traceable calibration for the Fluke 87-5 CAL is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents