Fluke 87V True Industrial Multimeter
The Fluke 87V True RMS Industrial Multimeter delivers accurate frequency measurements on adjustable speed drives and noisy equipment. It is designed to accurately measure voltage, current, frequency, resistance, capacitance, and temperature. It features a built-in thermometer, min/max/average recording, and a large display with a bright, two-level backlight.
- Model
- Fluke 87V
- Calibration
- Available on request
- Price
- $265
- Status
- In stock
- RFQ ref
- 87V
This unit
The Fluke 87V True Industrial Multimeter delivers precision diagnostics across motor drives, plant automation, power distribution, and electromechanical systems. Built for electrically noisy environments and high-altitude operation, it combines true-RMS measurement capability with a low-pass filter and shielding to handle variable frequency drive noise. Peak capture records transient events as fast as 250 µs, enabling rapid isolation of intermittent faults.
Technical Specifications Voltage & Current
DC Voltage: 1000 V maximum, ±(0.05% + 1) accuracy, 10 µV resolution
AC Voltage (True-RMS): 1000 V maximum, ±(0.7% + 2) accuracy to 20 kHz with low-pass filter, 0.1 mV resolution
DC Current: 10 A continuous (20 A for 30 seconds maximum), ±(0.2% + 2) accuracy, 0.01 µA or 0.1 µA resolution
AC Current (True-RMS): 10 A continuous (20 A for 30 seconds maximum), ±(1.0% + 2) accuracy, 0.1 µA resolution Passive & Frequency Measurements
Resistance: 50 MΩ maximum, ±(0.2% + 1) accuracy, 0.1 Ω resolution
Capacitance: 10,000 µF maximum, ±(1% + 2) accuracy, 0.001 µF resolution
Frequency: 200 kHz maximum, ±(0.005% + 1) accuracy, 0.01 Hz or 0.1 Hz resolution
Duty Cycle: 0–99.9% range, ±(0.2% per kHz + 0.1%) accuracy Temperature
Range: -200 to 1090 °C, ±1.0% accuracy (excluding probe)
Includes built-in thermometer and 80BK thermocouple probe
Key Features
True-RMS measurement on non-linear AC signals
Low-pass filter for adjustable speed drives and noisy electrical environments
Peak capture: 250 µs transient detection
Min/Max/Average recording
Diode and continuity testing with audible beeper
Relative mode for low-resistance measurement offset
Audible input alert for incorrect test lead placement
Large 4-1/2 digit display with two-level white backlight
Typical Applications Motor drive troubleshooting, variable frequency drive analysis, plant automation diagnostics, power distribution system testing, electromechanical equipment maintenance.
Compatibility & Integration 80BK thermocouple probe included for temperature measurement.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.01 Hz to 100 kHz | Voltage / Current Range: 600 mV to 1000 V, 600 µA to 20 A |
Fluke 87V — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 87V. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 87V faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 87V price
This Fluke 87V is listed at $265. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 87V calibration cost
NIST-traceable calibration for the Fluke 87V is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →