Fluke 88-5/A KIT Deluxe Automotive Multimeter Combo Kit

The Fluke 88-5/A KIT is a deluxe automotive multimeter combo kit designed for professional automotive technicians and mechanics. It includes the Fluke 88V digital multimeter, along with a selection of accessories for automotive diagnostics and troubleshooting. The kit provides comprehensive testing capabilities for automotive electrical systems, including voltage, current, resistance, frequency, and pulse width measurements. It also features specialized functions for testing automotive components such as ignition systems, fuel injectors, and sensors.

Model
Fluke 88-5/A KIT
Calibration
Available on request
Price
$760
Status
In stock
RFQ ref
88-5/A KIT
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 88-5/A KIT Deluxe Automotive Multimeter Combo Kit delivers professional-grade electrical diagnostics for automotive technicians. Built around the Fluke 88V digital multimeter, this kit integrates specialized accessories to troubleshoot conventional and hybrid vehicle electrical systems with precision and speed.

Technical Specifications Voltage & Current Measurement

DC Voltage: 0–1000 V, accuracy ±(0.1% + 1), resolution 0.01 mV

AC Voltage: 0–1000 V, accuracy ±(0.5% + 2), resolution 0.01 mV; True-RMS capable

DC Current: 0–10 A continuous (20 A for 30 s max), accuracy ±(0.4% + 2), resolution 0.001 mA

AC Current: 0–10 A continuous (20 A for 30 s max), accuracy ±(1.2% + 2), resolution 0.001 mA; True-RMS capable Passive Component Measurement

Resistance: 0–50 MΩ, accuracy ±(0.4% + 2), resolution 0.01 Ω

Capacitance: 0–10,000 µF

Conductance: 0–60.00 nS

Frequency: 0–200 kHz, accuracy 0.005%, resolution 0.01 Hz Temperature & Specialty Functions

Temperature range: -328.0°F to 1994.0°F (-200°C to 1090°C) via integrated thermometer

Duty cycle measurement: 0–99.9%

Diode test and continuity check with audible indication

Key Features

Pulse width measurement at millisecond resolution for fuel injector diagnostics

RPM measurement with optional inductive pickup; supports conventional and waste spark ignition

Peak Min/Max capture down to 250 µs for transient and intermittent fault detection

Min/Max/Average recording with automatic Min/Max Alert function

10 MΩ input impedance protects sensitive vehicle computer circuits

Auto HOLD captures stable readings on noisy signals; auto and manual ranging

Input Alert provides audible feedback for incorrect jack selection

Relative Mode removes test lead resistance from low-ohm measurements

Typical Applications Battery and charging system testing, starter motor diagnostics, fuel injector pulse width analysis, ignition circuit troubleshooting, sensor output verification, and continuity checks on automotive wiring harnesses.

Compatibility & Integration The kit combines the Fluke 88V with specialized accessories designed for automotive electrical work on both conventional and hybrid powertrains.

Specifications

ParameterValue
Frequency Range0–200 kHz | Voltage / Current Range: 0–10 A continuous (20 A for 30 s max), 0–1000 V DC/AC

Fluke 88-5/A KIT — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 88-5/A KIT. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 88-5/A KIT faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 88-5/A KIT price

This Fluke 88-5/A KIT is listed at $760. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 88-5/A KIT calibration cost

NIST-traceable calibration for the Fluke 88-5/A KIT is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents