Keithley 2000-182-02B

Keithley Laboratory Measurement Instruments.

Model
Keithley 2000-182-02B
Calibration
Available on request
Price
$750
Status
In stock
RFQ ref
2000-182-02B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 2000-182-02B is a 6.5-digit digital multimeter engineered for high-precision measurements in R&D, automated test systems, production, and quality control environments. This half-rack instrument delivers DC voltage accuracy of 0.002% and DC resistance accuracy of 0.008% over a 90-day interval, with measurement speeds up to 2000 readings/second at 4.5 digits or 50 triggered readings/second at full 6.5-digit resolution over IEEE-488.

Technical Specifications The meter measures DC voltage from 100 nV to 1 kV and AC voltage (RMS) from 0.1 µV to 750 V (1000 V peak). Current measurement spans 10 nA to 3 A DC and 1 µA to 3 A AC (RMS). Resistance measurements operate in both two-wire and four-wire modes from 100 µΩ to 120 MΩ. Frequency and period measurements cover 3 Hz to 500 kHz. Temperature sensing supports Type J, K, and T thermocouples and RTDs, with Type K range from −200°C to +1372°C. AC voltage accuracy is specified at 0.05% (90-day basic). The instrument changes ranges in less than 30 ms and functions in 45/s. Input protection includes 1000 V across DCV, resistance, temperature, continuity, and diode test functions on all ranges; ACI protection uses a 3 A, 250 V fuse; ACV accepts 1000 V peak with maximum 400 V DCV on any ACV range.

Key Features

Continuity testing with adjustable 1 Ω to 1000 Ω threshold

Diode test and peak spike detection (high and low)

dB/dBm, ratio, and crest factor measurements

Time stamp capability for data logging

Math functions: mX+b, min/max/average/standard deviation, limit test, percent, and null/relative

SCPI programming with Keithley 196/199 and Fluke 8840A/8842A emulation modes

IEEE-488.2 (GPIB) and RS-232C interfaces

Universal 90–134 V and 180–264 V AC power (50 Hz / 60 Hz)

Typical Applications Production testing, quality control, component verification, and multipoint automated measurements.

Compatibility & Integration Optional plug-in scanner cards such as the 2000-SCAN (10-Channel) enable multipoint measurements. The meter integrates with Keithley's 7000 Series switch matrices and cards for systems exceeding ten measurement points.

Specifications

ParameterValue
Frequency Range3 Hz to 500 kHz | Voltage / Current Range: DC Voltage: 100 nV to 1 kV
AC Voltage0.1 µV to 750 V (1000 V peak)
DC Current10 nA to 3 A
AC Current1 µA to 3 A

Keithley 2000-182-02B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 2000-182-02B. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 2000-182-02B faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 2000-182-02B price

This Keithley 2000-182-02B is listed at $750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 2000-182-02B calibration cost

NIST-traceable calibration for the Keithley 2000-182-02B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →