Fluke 233-NIST Remote Display Multimeter with detachable display

The Fluke 233-NIST Remote Display Multimeter features a detachable display for added flexibility and safety. This allows users to take measurements in hard-to-reach or hazardous areas, while still being able to view the readings. NIST-traceable calibration ensures accuracy and reliability.

Model
Fluke 233-NIST
Calibration
Available on request
Price
$430
Status
In stock
RFQ ref
233-NIST
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 233-NIST Remote Display Multimeter delivers true-rms electrical measurements with a detachable wireless display capable of operating up to 33 feet (10 meters) from the meter body. This separation enables safer measurements in hazardous environments and reduces arc flash risk by positioning the user away from the test point. A single technician can now perform tasks traditionally requiring two people, improving field efficiency while maintaining NIST-traceable measurement accuracy.

Technical Specifications Measurement Ranges & Accuracy:

DC Voltage: 0.1 mV to 1000 V, ±(0.25% + 2 counts)

AC Voltage: 0.1 mV to 1000 V, ±(1.0% + 3 counts)

DC Current: 0.1 mA to 10 A, ±(1.0% + 3 counts)

AC Current: 0.1 mA to 10 A, ±(1.5% + 3 counts)

Resistance: 0.1 Ω to 40 MΩ

Capacitance: 1000 nF to 9999 µF

Frequency: 0.1 Hz to 50 kHz, 0.01 Hz resolution

Temperature: -40°C to 400°C Display & Performance:

6,000 counts resolution

Wireless remote display with magnetic mounting

2.4 GHz ISM band communication Power & Battery:

Meter body: 3 × AA alkaline batteries

Display unit: 2 × AA alkaline batteries

Battery life: approximately 400 hours typical

Auto-off function extends runtime Physical & Safety:

Dimensions: 19.3 × 5.3 × 5.3 cm (7.6 × 2.08 × 2.08 inches)

Weight: 604 g (1.3 lb)

Rubber overmold protection

CAT IV 600 V, CAT III 1000 V rated

True-rms AC measurements on non-linear signals

Key Features

Detachable wireless display operates independently up to 33 feet away

NIST-traceable calibration certificate with full data and uncertainties

True-rms measurement capability for distorted AC waveforms

Positions hazardous measurement points away from the operator

Single-technician operation eliminates two-person workflow requirements

Typical Applications Electrical troubleshooting in confined or high-voltage environments where operator safety is critical. Equipment commissioning and preventive maintenance on energized systems. Field diagnostics requiring NIST-certified measurement traceability.

Compatibility & Integration Includes test leads, alligator clips, temperature probe, and CD-ROM documentation. All accessories ship with the unit.

Specifications

ParameterValue
Frequency Range0.1 Hz to 50 kHz | Voltage / Current Range: DC Voltage: 0.1 mV to 1000 V
AC Voltage0.1 mV to 1000 V
DC Current0.1 mA to 10 A
AC Current0.1 mA to 10 A

Fluke 233-NIST — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 233-NIST. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 233-NIST faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 233-NIST price

This Fluke 233-NIST is listed at $430. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 233-NIST calibration cost

NIST-traceable calibration for the Fluke 233-NIST is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →