HP / Agilent 3455A 5 or 6-Digit Digital Multimeter/Voltmeter
HP / Agilent Laboratory Measurement Instruments. Voltage: 0.1 V to 1000 V with 1 µV sensitivity, Voltage: 1 V to 1000 V (standard True RMS, Voltage: greater than 140 dB normal mode rejection.
- Model
- HP / Agilent 3455A
- Calibration
- Available on request
- Price
- $1,762
- Status
- In stock
- RFQ ref
- 3455A
This unit
The HP/Agilent 3455A is a microprocessor-controlled digital multimeter delivering 5.5 or 6.5-digit resolution for benchtop and systems measurement applications. It measures DC voltage, AC voltage, and resistance with exceptional accuracy and noise rejection, making it ideal for precision laboratory and industrial work. The instrument features fully guarded circuitry, internal auto-calibration, and dual-mode resolution for measurements approaching 1 part per million in DC and resistance.
Technical Specifications Measurement Functions & Ranges
DC Voltage: 0.1 V to 1000 V with 1 µV sensitivity
AC Voltage: 1 V to 1000 V (standard True RMS, 30 Hz to 1 MHz); optional Average Converter supports 30 Hz to 250 kHz
Resistance: 0.1 kΩ to 10 MΩ in six ranges, 2-wire and 4-wire modes Resolution & Display
5.5 or 6.5-digit digital display
High-resolution mode enables DC and resistance measurements exceeding 1 ppm accuracy Reading Rates
DC ranges: up to 24 readings/s
Resistance: up to 12 readings/s
AC Fast Mode: up to 13 readings/s (frequencies above 300 Hz)
Remote operation supports variable rates including 24, 22, 6, and 5 rdg/s depending on configuration Accuracy (90-day, 23°C ±5°C)
DC Voltage - 1 V range: ±(0.006% + 3 to 4 counts); 10 V: ±(0.005% + 3 counts); 100/1000 V: ±(0.007% + 3 counts)
Resistance (4-wire) - 1 kΩ: ±(0.0035% + 5 counts); 10 kΩ: ±(0.0060% + 5 counts); 100 kΩ: ±(0.0035% + 6 counts); 1000 kΩ: ±(0.0135% + 5 counts); 10,000 kΩ: ±(0.1000% + 5 counts)
AC Voltage - 30 Hz to 20 kHz: ±(0.05% + 50 counts); 20 kHz to 100 kHz: ±(0.5% + 100 counts)
Temperature Coefficient (10 V DC): ±(0.002% + 0.05 counts)/°C Noise Rejection
DC ranges: greater than 60 dB normal mode rejection
AC voltage: greater than 140 dB normal mode rejection
Key Features
Auto Calibration (Auto Cal) digitally corrects DC voltage and resistance circuits against internal references
True RMS AC converter handles sinusoidal and complex signals with crest factors to 7:1 at full scale
Fully guarded circuit design minimizes measurement errors in noisy environments
Math functions included
Typical Applications Precision DC and AC measurements in research labs, production testing, and systems integration where sub-ppm accuracy and high noise rejection are required.
Compatibility & Integration Remote operation capable with configurable reading rates for automated test systems and data acquisition setups.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 30 Hz to 1 MHz | Voltage / Current Range: DC: 0.1 V to 1000 V |
| AC | 1 V to 1000 V |
HP / Agilent 3455A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3455A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 3455A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
HP / Agilent 3455A price
This HP / Agilent 3455A is listed at $1,762. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 3455A calibration cost
NIST-traceable calibration for the HP / Agilent 3455A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →