Anritsu 68095B Synthesized CW Generator, 0.5 – 65.0 GHz
Anritsu 68095B,Generates stable CW signals from 0.5 GHz to 65 GHz. Perfect for high-frequency testing with precise signal output and excellent spectral purity. Supports automated control and modulation.
- Model
- Anritsu 68095B
- Calibration
- Available on request
- Price
- $28,479
- Status
- In stock
- RFQ ref
- 68095B
This unit
The Anritsu 68095B is a synthesized CW generator delivering phase-locked continuous wave signals across 0.5 GHz to 65.0 GHz. Purpose-built for telecommunications, aerospace, and defense testing, this instrument generates stable, spectrally pure signals with exceptional frequency resolution and dynamic range control.
Technical Specifications
Frequency Range: 0.5 GHz to 65.0 GHzFrequency Resolution: 0.01 Hz
Output Power: −110 dBm to +20 dBm Signal Purity:
- Phase Noise: −120 dBc/Hz at 10 kHz offset (typical)
- Harmonics: < −60 dBc
- Non-Harmonics: < −80 dBc
- Spurious: < −80 dBc Modulation: Internal AM, FM, phase modulation, and pulse modulation. User-downloaded complex modulation capability supported. Sweep & Agility:
- Step sweep with 1 ms to 99 seconds dwell time
- Switching time: < 15 ms + 1 ms/GHz or < 40 ms typical maximum
- Alternate sweep mode between two ranges with independent power selection
- Manual sweep with phase-locked frequency adjustment
- Programmable frequency list: up to 1000 non-sequential frequencies via GPIB Interfaces: GPIB, USB, LAN Physical: 425 mm × 177 mm × 500 mm; 25 kg
Key Features
- 0.01 Hz frequency resolution enables precise carrier placement and test repeatability
- Low phase noise and high spectral purity suit demanding metrology and component characterization
- Multiple sweep modes
CW, step, alternate, and manual - address diverse measurement workflows
Frequency list storage accommodates rapid multi-point stimulus sequences without settling delays
Typical Applications
- High-frequency component characterization and gain/phase measurement
- Receiver sensitivity and dynamic range testing
- Antenna pattern and directivity evaluation
- System integration and end-to-end performance validation
Compatibility & Integration The 68095B integrates with Anritsu and HP/Agilent accessories and modules. Instrument drivers support LabWindows and GPIB-based automated test environments, enabling direct control and real-time parameter adjustment within existing measurement frameworks.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.5 GHz to 65.0 GHz | Power Range (dBm): −110 dBm to +20 dBm |
Anritsu 68095B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 68095B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 68095B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 68095B price
This Anritsu 68095B is listed at $28,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 68095B calibration cost
NIST-traceable calibration for the Anritsu 68095B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →