Fluke 75 Series II Digital Multimeter

The Fluke 75 Series II Digital Multimeter is a handheld device designed for electrical troubleshooting. It measures voltage, current, and resistance with high accuracy. Features include a large display, auto-ranging, and data hold.

Model
Fluke 75 Series II
Calibration
Available on request
Price
$85
Status
In stock
RFQ ref
75 Series II
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 75 Series II is a handheld digital multimeter engineered for electrical troubleshooting and field measurements across professional maintenance, service, and diagnostic applications. It combines a 3200-count digital display with a 31-segment analog bar graph - updating at 2.5 Hz and 25 Hz respectively - to deliver precise numerical readings and real-time trend visualization. The instrument measures DC voltage (320 mV to 1000 V), AC voltage (3.2 V to 750 V, sine wave), DC current (32 mA to 10 A), AC current (32 mA to 10 A), and resistance (320 Ω to 32 MΩ). Additional functions include continuity testing with a 4096 Hz audible beeper and diode testing with 2.8 V measurement voltage and 1% accuracy.

Technical Specifications

Display: 3½-digit, 3200-count digital with 31-segment analog bar graph

Update Rate: Digital 2.5 Hz; Analog bar graph 25 Hz

DC Voltage Accuracy: ±(0.4% + 1)

AC Voltage Accuracy: ±(2% + 2) on 45 Hz to 500 Hz (750 V range) and 45 Hz to 1 kHz (3.2 V and 32 V ranges)

DC Current Accuracy: ±(1.5% + 2)

AC Current Accuracy: ±(2.5% + 2)

Resistance Accuracy: ±(0.5% + 1)

Input Impedance: 10 MΩ / 50 pF (VDC, mVDC, VAC)

Maximum Overvoltage Rating: 1000 V DC; 750 V AC RMS (sine)

Fuse Protection: 300/630 mA, 250 V; 10/15 A, 600 V (Fast)

Key Features

Manual and automatic ranging for flexible field operation

Touch Hold captures and displays stable readings automatically

9V battery (NEDA 1604, 6F22, or 006P) with Sleep Mode extending runtime beyond 2000 hours (alkaline)

Auto power-off with sleep function preserves battery life

Diode forward voltage drop (Vf) measurement at 2.8 V

Ergonomic case with removable holster

IEC 348, ANSI/ISA-S82, UL1244, and CSA C22.2 No.231 compliant

Physical Specifications

Dimensions: 2.8 cm H × 7.5 cm W × 16.6 cm L

Weight: 340 g

Battery Life: 2000 hours typical (alkaline); 1600 hours typical (carbon zinc)

Typical Applications Electrical troubleshooting, preventive maintenance, HVAC service diagnostics, control circuit verification, and general field testing where dual display feedback enhances measurement confidence.

Specifications

ParameterValue
Voltage / Current RangeVDC: 320 mV to 1000 V
VAC3.2 to 750 V
ADC/AAC32 mA to 10 A

Fluke 75 Series II — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 75 Series II. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 75 Series II faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 75 Series II price

This Fluke 75 Series II is listed at $85. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 75 Series II calibration cost

NIST-traceable calibration for the Fluke 75 Series II is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →