Keithley 2001 Series: 7.5 Digit Multimeter with Scanning

Keithley Laboratory Measurement Instruments. Voltage: 1 µV to 20 V single range, Voltage: Up to 750 V, Current: Up to 2 A.

Model
Keithley 2001
Calibration
Available on request
Price
$1,730
Status
In stock
RFQ ref
2001
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 2001 Series is a 7.5-digit multimeter engineered for precision measurement and automated data acquisition in laboratory, engineering, and system integration environments. Built on a 28-bit A/D converter, it delivers true 7.5-digit resolution across DC voltage, AC voltage, current, resistance, frequency, and temperature measurements. The instrument supports single-range DC voltage measurement from 1 µV to 20 V, eliminating range-shift errors and delays. Optional scanning capabilities enable multi-point automated testing with up to ten measurement points, reducing test cycle time and operator intervention.

Technical Specifications Voltage & Current Measurement

DC Voltage: 1 µV to 20 V single range; 0.0018% basic accuracy; input resistance >10 GΩ on 20 V, 2 V, 200 mV ranges

AC Voltage: Up to 750 V; better than 0.1% accuracy down to 1 Hz; TRMS, average, peak, AC+DC, and crest factor modes; peak detection captures 1 µs spikes

DC Current: Up to 2 A

AC Current: Up to 2 A Resistance & Specialized Functions

Resistance: Up to 1000 Ω using unique single-phase 4-wire method, twice as fast as competitive techniques; built-in open-lead detection

Frequency: 1 Hz to 15 MHz at ±(0.03% of reading) accuracy

Temperature measurement supported; continuity test included Performance

Speed: Over 2000 readings/second at 4.5-digit resolution; up to 44 readings/second at full 7.5-digit accuracy for DCV and ohms

Trigger response: Less than 2 µs ±1 µs

Memory options: 8K, 32K, or 128K configurations available

Key Features

28-bit A/D converter enables minute signal discrimination and extended dynamic range

Scanning options: 10-channel card (2000-SCAN), 10-channel with dual high-speed channels (2001-SCAN), or 9-channel thermocouple card (2001-TCSCAN)

High-speed function and range switching

Greater dynamic range supports measurements from 1 µV to 20 V on single range

Typical Applications Precision engineering measurements, multi-point automated test systems, laboratory data acquisition, enterprise-level quality assurance, transient capture for power supply analysis.

Compatibility & Integration Scanner card integration accommodates multi-channel test configurations for streamlined production and field testing workflows.

Specifications

ParameterValue
Frequency Range1 to 1400 MHz | Power Range (dBm): '+10 dBm to −80 dBm (or +9 dBm to −81 dBm) | Voltage / Current Range: 115/230 VAC ±10%, 50–60 Hz, approximately 20 W

Keithley 2001 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 2001. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 2001 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 2001 price

This Keithley 2001 is listed at $1,730. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 2001 calibration cost

NIST-traceable calibration for the Keithley 2001 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →